FRP Cooling Towers for Data Centers

Our modular FRP counterflow cooling tower cells serve data center chillers and liquid-cooling loops. The FRP casing and basin do not rust.

Price by written quotation

Include the quantity and destination. Specification and supply details are confirmed for the inquiry.

Key parameters

Tower type
Square counterflow, modular cells
Standard design condition
Inlet 37 °C / outlet 32 °C, wet-bulb 28 °C (reference GB/T 7190.1)
Single-tower flow range
Below 1,000 m³/h per tower (larger by multiple cells)
Full specifications

Technical specifications

Parameter Typical value
Tower type Square counterflow, modular cells
Standard design condition Inlet 37 °C / outlet 32 °C, wet-bulb 28 °C (reference GB/T 7190.1)
Single-tower flow range Below 1,000 m³/h per tower (larger by multiple cells)
Casing / basin FRP
Fill PVC film fill (other types on request)
Standard grade High-performance grade
Option Standard drift eliminators and fans for general data-center heat rejection. High-efficiency drift eliminators and low-noise fans for strict water-use or noise limits.

Design references: drift and noise

Parameter Standard grade High-performance grade Conditions
Drift loss About 0.005–0.010% of circulating flow About 0.001–0.002% Designed with reference to GB/T 7190.1 / CTI ATC-140
Noise Standard noise class by flow Low / ultra-low noise classes Noise class by flow with reference to GB/T 7190.1; site noise checked separately
Thermal performance At standard condition At your design condition Confirmed by selection for your flow, range and wet-bulb

Values outside these ranges: custom designs are available on request.

Listed values are selection references, not ratings for every configuration. The agreed specification identifies the selected dimensions, materials and required evidence. Standards cited here are design references, not certification claims; custom dimensions depend on the product and tooling.

FIBROVX FRP cooling towers for data centers are modular, square counterflow cooling tower cells that reject heat from chillers and liquid-cooling loops. The FRP casing and basin do not rust, and cells can be added as IT load grows, with spare cells for redundancy.

Key highlights: sized from flow, inlet / outlet temperature and wet-bulb; drift eliminators reducing drift to about 0.005–0.010% of circulating water (0.001–0.002% high-efficiency); low-noise fan options; thermal and noise performance designed with reference to GB/T 7190.1 and CTI test methods.

Key benefits

  • Modular cells for phased expansion and N+1 redundancy
  • Corrosion-free FRP casing and basin
  • Low-noise fan and motor options for urban sites
  • High-efficiency drift eliminators to limit water loss
  • Easy access for fill, nozzle and fan maintenance

Customization options

  • Cell size, number of cells and layout
  • Fan, motor and VFD options
  • Fill type and drift eliminator efficiency
  • Basin, walkways, ladders and handrail

Exact sizes, resin systems, colors and accessories are confirmed at quotation for your drawings and operating conditions. FIBROVX manufactures to order and supports OEM / private-label marking where agreed.

Typical applications

  • Data-center chiller condenser water
  • Liquid-cooling and free-cooling loops
  • Telecom and edge-computing plant rooms
  • Retrofit of corroded steel towers

FAQ

What information do you need to size the towers?
Circulating flow, inlet and outlet water temperatures, design wet-bulb, redundancy target and any noise or footprint limits.

Can towers be added later?
Yes. Modular cells can be planned so that more cells are added as load grows.