{"product_id":"frp-data-centre-cooling-towers","title":"FRP Cooling Towers for Data Centers","description":"\u003cp\u003eFIBROVX FRP cooling towers for data centers are modular, square counterflow cooling tower cells that reject heat from chillers and liquid-cooling loops. The FRP casing and basin do not rust, and cells can be added as IT load grows, with spare cells for redundancy.\u003c\/p\u003e\n\u003cp\u003eKey highlights: sized from flow, inlet \/ outlet temperature and wet-bulb; drift eliminators reducing drift to about 0.005–0.010% of circulating water (0.001–0.002% high-efficiency); low-noise fan options; thermal and noise performance designed with reference to GB\/T 7190.1 and CTI test methods.\u003c\/p\u003e\n\u003ch3\u003eKey benefits\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eModular cells for phased expansion and N+1 redundancy\u003c\/li\u003e\n\u003cli\u003eCorrosion-free FRP casing and basin\u003c\/li\u003e\n\u003cli\u003eLow-noise fan and motor options for urban sites\u003c\/li\u003e\n\u003cli\u003eHigh-efficiency drift eliminators to limit water loss\u003c\/li\u003e\n\u003cli\u003eEasy access for fill, nozzle and fan maintenance\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCustomization options\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCell size, number of cells and layout\u003c\/li\u003e\n\u003cli\u003eFan, motor and VFD options\u003c\/li\u003e\n\u003cli\u003eFill type and drift eliminator efficiency\u003c\/li\u003e\n\u003cli\u003eBasin, walkways, ladders and handrail\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eExact sizes, resin systems, colors and accessories are confirmed at quotation for your drawings and operating conditions. FIBROVX manufactures to order and supports OEM \/ private-label marking where agreed.\u003c\/p\u003e\n\u003ch3\u003eTypical applications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eData-center chiller condenser water\u003c\/li\u003e\n\u003cli\u003eLiquid-cooling and free-cooling loops\u003c\/li\u003e\n\u003cli\u003eTelecom and edge-computing plant rooms\u003c\/li\u003e\n\u003cli\u003eRetrofit of corroded steel towers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"fibrovx-spec\"\u003e\n\u003ch3\u003eTechnical specifications\u003c\/h3\u003e\n\u003cdiv class=\"fx-table-wrap\" style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;max-width:calc(100vw - 40px)\"\u003e\u003ctable style=\"width:100%;min-width:0;border-collapse:collapse;font-size:0.95em;overflow-wrap:break-word\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eParameter\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eTypical value\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eTower type\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eSquare counterflow, modular cells\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eStandard design condition\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eInlet 37 °C \/ outlet 32 °C, wet-bulb 28 °C (reference GB\/T 7190.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eSingle-tower flow range\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eBelow 1,000 m³\/h per tower (larger by multiple cells)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eCasing \/ basin\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eFRP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eFill\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003ePVC film fill (other types on request)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv class=\"fx-table-wrap\" style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;max-width:calc(100vw - 40px)\"\u003e\u003ctable style=\"width:100%;min-width:0;border-collapse:collapse;font-size:0.95em;overflow-wrap:break-word\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003e\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eStandard grade\u003c\/th\u003e\n\u003cth style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eHigh-performance grade\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eOption\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eStandard drift eliminators and fans for general data-center heat rejection.\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eHigh-efficiency drift eliminators and low-noise fans for strict water-use or noise limits.\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eDesign references: drift and noise\u003c\/h3\u003e\n\u003cdiv class=\"fx-table-wrap\" style=\"overflow-x:auto;-webkit-overflow-scrolling:touch;margin:0 0 1em;max-width:calc(100vw - 40px)\"\u003e\u003ctable style=\"width:100%;min-width:0;border-collapse:collapse;font-size:0.95em;overflow-wrap:break-word\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth scope=\"col\" style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eParameter\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eStandard grade\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eHigh-performance grade\u003c\/th\u003e\n\u003cth scope=\"col\" style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top;background:#f2f4f7;font-weight:600\"\u003eConditions\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eDrift loss\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eAbout 0.005–0.010% of circulating flow\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eAbout 0.001–0.002%\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eDesigned with reference to GB\/T 7190.1 \/ CTI ATC-140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eNoise\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eStandard noise class by flow\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eLow \/ ultra-low noise classes\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eNoise class by flow with reference to GB\/T 7190.1; site noise checked separately\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eThermal performance\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eAt standard condition\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eAt your design condition\u003c\/td\u003e\n\u003ctd style=\"border:1px solid #d0d5dc;padding:8px 10px;text-align:left;vertical-align:top\"\u003eConfirmed by selection for your flow, range and wet-bulb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eValues outside these ranges: custom designs are available on request.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eListed values are selection references, not ratings for every configuration. The agreed specification identifies the selected dimensions, materials and required evidence. Standards cited here are design references, not certification claims; custom dimensions depend on the product and tooling.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eRelated products\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/frp-cooling-towers\"\u003eFRP Cooling Towers\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/cooling-tower-fill-media\"\u003eCooling Tower Fill Media\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/frp-fans\"\u003eFRP Fans\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/frp-handrail-systems\"\u003eFRP Handrail Systems\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eGuides and resources\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/frp-guides\/frp-cooling-towers-guide\"\u003eFRP Cooling Towers Guide\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/blogs\/frp-guides\/cooling-tower-sizing-basics-range-approach-wet-bulb\"\u003eCooling Tower Sizing Basics\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/industries\"\u003eIndustries we serve\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/technical-resources\"\u003eTechnical resources\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/pages\/international-delivery\"\u003eInternational delivery\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat information do you need to size the towers?\u003c\/strong\u003e\u003cbr\u003eCirculating flow, inlet and outlet water temperatures, design wet-bulb, redundancy target and any noise or footprint limits.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan towers be added later?\u003c\/strong\u003e\u003cbr\u003eYes. Modular cells can be planned so that more cells are added as load grows.\u003c\/p\u003e\n\u003ch3\u003eHow to inquire\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHeat load or circulating flow\u003c\/li\u003e\n\u003cli\u003eWater temperatures and design wet-bulb\u003c\/li\u003e\n\u003cli\u003eRedundancy (N+1 etc.), noise and footprint limits\u003c\/li\u003e\n\u003cli\u003eSite water quality and access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eRequest a quote\u003c\/h3\u003e\n\u003cp\u003ePricing is by quotation only. Use the \u003ca href=\"\/pages\/request-a-quote?product=frp-data-centre-cooling-towers\u0026amp;title=FRP+Cooling+Towers+for+Data+Centres\"\u003eRequest a Quote\u003c\/a\u003e form with your drawing, quantity and destination, or \u003ca href=\"\/pages\/contact\"\u003econtact FIBROVX\u003c\/a\u003e. Packing method, lead time and Incoterms are confirmed in each quotation — available on request.\u003c\/p\u003e\n","brand":"FIBROVX","offers":[{"title":"Default Title","offer_id":67902702125165,"sku":null,"price":0.0,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0847\/0088\/9197\/files\/frp-cooling-towers-square_45876fc1-f84f-46b3-aac7-daf1d2ba1a98.jpg?v=1793323151","url":"https:\/\/fibrovx.com\/products\/frp-data-centre-cooling-towers","provider":"FIBROVX","version":"1.0","type":"link"}